ES930 – Multi-I/O Module
Functions
- Multi-I/O- module for prototyping, testing and calibration
- High performance with numerous functions
- 16 different input channels: 4 thermo, 8 analog, 4 digital
- 4 sensor power supplies
- 10 different output channels
- 6 half-bridges with current measurement, controlled by digital outputs
Technical data
Thermo channels (TH) | |
Thermo channels (TH)
Number of channels
|
4, thermocouples type K
|
Thermo channels (TH)
Measuring range
|
73 °F to 2501 °F / -200 °C to +1372 °C
|
Thermo channels (TH)
Analog input channels (AI)
|
|
Thermo channels (TH)
Number of channels
|
8
|
Thermo channels (TH)
Measuring range, resolution
|
±1 V, ±10 V, ±60 V for differential input voltages, 16 bit
|
Thermo channels (TH)
Anti-aliasing filter (hardware filter)
|
Low-pass, 2nd order (Bessel), 3 dB limit frequency 10 kHz
|
Thermo channels (TH)
Digital low-pass filter
|
Digital FIR low-pass 8th order (Butterworth) with adjustable limit frequency, switched
|
Thermo channels (TH)
Digital input channels (DI)
|
|
Thermo channels (TH)
Number of channels
|
4
|
Thermo channels (TH)
Input voltage
|
0 V to 5 V, TTL-compatible
|
Thermo channels (TH)
Counter width, resolution
|
32 Bit, 15 ns
|
Thermo channels (TH)
Functionality
|
Active time, inactive time, counter, state; event raster generation
|
Thermo channels (TH)
Glitch filter
|
120 ns to 3000 ns or “Off”, resolution 15 ns
|
Thermo channels (TH)
Timeout
|
Configurable per channel: 0.1 s to 64.4 s or “Off”
|
Thermo channels (TH)
Events
|
4 event sources per module can be configured differently
|
Thermo channels (TH)
Event functionality
|
Triggering a synchronous data acquisition on the ES930 module;
|
Thermo channels (TH)
|
triggering the model trigger in the ES910 Prototyping and Interface Module
|
Thermo channels (TH)
Analog output channels (AO)
|
|
Thermo channels (TH)
Number of channels
|
4
|
Thermo channels (TH)
Output voltage, resolution
|
0 V to +10 V, 14 bit
|
Thermo channels (TH)
Output current
|
±4 mA (max.)
|
Thermo channels (TH)
Digital output channels (DO)
|
|
Thermo channels (TH)
Number of channels
|
6
|
Thermo channels (TH)
Output voltage
|
TTL-compatible
|
Thermo channels (TH)
Counter width, resolution
|
32 bit, 15 ns
|
Thermo channels (TH)
Functions
|
PWM Out, Pulse Out, Digital Out; simultaneously control of the half-bridges (PS); configurable synchronous channel groups
|
Thermo channels (TH)
Pulse width
|
150 ns to 64.4 s; fmax = 30 kHz at 95% duty cycle
|
Thermo channels (TH)
Control of half-bridges
|
2.5 μs to 64.4 s; fmax = 20 kHz at 95% duty cycle
|
Thermo channels (TH)
Power stages/Half bridges (PS)
|
|
Thermo channels (TH)
Number of channels
|
6, one digital output controls both switches of one half-bridge
|
Thermo channels (TH)
Power supply
|
Separate: 7 V to 32 V DC
|
Thermo channels (TH)
Switching current
|
±5 A rated current (max., per channel)
|
Thermo channels (TH)
|
±7 A short-term voltage peaks (max., per channel)
|
Thermo channels (TH)
|
20 A (max., rated current at power supply plus or minus)
|
Thermo channels (TH)
Frequency
|
20 kHz (max.)
|
Thermo channels (TH)
Pulse width
|
2.5 μs to 64.4 s
|
Thermo channels (TH)
Current input of the half-bridges
|
|
Thermo channels (TH)
Number of channels
|
6, current measurement with shunt in output path of half-bridge switch
|
Thermo channels (TH)
Input measuring range
|
-5 A to 5 A (clipping)
|
Thermo channels (TH)
Anti-aliasing filter (hardware filter)
|
Low pass 1st order, 3 dB limit frequency 15 kHz
|
Thermo channels (TH)
Digital filter (software)
|
Configurable per module: Off, CIC filter (sic filter), IIR filter 2nd order (Bessel)
|
Thermo channels (TH)
Sensor supply
|
|
Thermo channels (TH)
Number of channels
|
4, assigned to sensors or input channels
|
Thermo channels (TH)
Output voltage
|
+5 V to +15 V DC or “Off”, configurable per channel, resolution <10 mV
|
Thermo channels (TH)
Output current
|
50 mA (max. per channel at 5 V)
|
Thermo channels (TH)
|
30 mA (max. per channel at 15 V, all channels loaded simultaneously)
|
Thermo channels (TH)
Host interface
|
|
Thermo channels (TH)
Ethernet interface and protocols
|
100Base-T, Full-Duplex required, XCP-on-UDP/IP
|
Thermo channels (TH)
IP-Address
|
Dynamic via INCA or ES93x Configuration Tool
|
Thermo channels (TH)
Power supply
|
|
Thermo channels (TH)
Operating voltage for the module at "IN" connection
|
6 V to 32 V DC
|
Thermo channels (TH)
Environment
|
|
Thermo channels (TH)
Operating temperature range
|
-40 °F to +158 °F / -40 °C to +70 °C
|
Thermo channels (TH)
Protection class
|
IP30
|
Thermo channels (TH)
Mechanical data
|
|
Thermo channels (TH)
Dimensions (H x W x D)
|
73 mm x 128 mm x 174 mm / 2.9 in x 5.0 in x 6.8 in
|
Thermo channels (TH)
Weight
|
Approx. 1.1 kg / 2.4 lbs
|
Thermo channels (TH)
Supported by ETAS software for configuration, control, or data recording
|
|
Thermo channels (TH)
General
|
ES93x Configuration Tool V1.3.0 and higher
HSP V9.5.0 and higher |
Thermo channels (TH)
Measurement and calibration (MC)
|
INCA V7.0.0 Hotfix 4 and higher with INCA Add-On ES93x V1.3.0 and higher
|
Thermo channels (TH)
Rapid Protoyping (RP)
|
INTECRIO V4.0 and higher, ASCET-RP V6.1.3 and higher
|
This product has been developed and released for use in automotive applications. For usage in other domains please contact your ETAS representative.
Contact us
Do you have any questions? Feel free to send us a message. We will be more than happy to help.
Contact us today!