Skip to main content
ES882

ES882 – BR_XETK ECU and bus interface module

ES882 – BR_XETK ECU and Bus Interface Module

Using the ES882 BR_XETK ECU and Bus Interface Module, Automotive Ethernet ECUs and vehicle buses can be connected to the ES800 measurement, calibration and prototyping system. Together with the BroadR-Reach® BR_XETK ECU interface and the INCA software tool, ETAS offers a solution for the validation and calibration of interconnected electronic systems in the vehicle and on the test bench that aims to optimize overall integration efforts.

Important functions

In addition to the Ethernet, CAN, CAN FD and LIN vehicle buses, the ES882 module supports the BR_XETK and XETK ECU interfaces from ETAS. Three BR_XETKs can be connected to one ES882 module simultaneously. Measurement modules from the ES400 or ES600 product families as well as ES523, ES592, ES593-D and ES595 ECU and Bus Interface Modules and ES9xx Prototyping and Bus Interface Modules can be connected to the ES882 module via Fast Ethernet.

Applications

  • Calibration and prototyping of ECUs via Automotive Ethernet
  • Measurements in the vehicle and on the test bench with high data rates

Your benefits

  • Open interfaces for integration into existing tool environments
  • Time-synchronous acquisition of signals from BR_XETK and XETK ECUs, vehicle buses, and measurement modules with an accuracy greater than 1 µs using ETAS hardware
  • Time synchronization compliant with IEEE-1588 standard
  • Seamless integration in INCA and BUSMASTER
  • Three BroadR-Reach® BR_XETK/Automotive Ethernet ports, one Gigabit Ethernet port, and one XETK/Fast Ethernet port
  • Five CAN/CAN FD interfaces
  • One LIN interface
  • Wake-up on CAN and wake-up on CAN FD
  • Simple plug-in mechanism for connecting additional modules from the ES800 family
  • Robust metal housing (IP44)

Technical data

Size and weight
Size and weight
Dimensions (HxWxD)
63 mm x 215 mm x 230 mm / 2.47 in x 8.46 in x 9.06 in (housing)
Size and weight
Weight
2.9 kg / 6.44 lb
Size and weight
Environment
Size and weight
Temperature range
-40°C to +70°C / -40 °F to +158 °F (operation)
Size and weight
-40°C to +85°C / -40 °F to +185 °F (storage)
Size and weight
Relative humidity
85 % (Operation) 95 % (Storage), non-condensing
Size and weight
Robustness
Mechanical shock, vibration, free fall, temperature change, in accordance with ISO 16750 and DIN EN 60068
Size and weight
Protection class
IP44
Size and weight
Operating altitude
Maximum 5,000 m above sea level
Size and weight
Supply
Size and weight
Operating voltage
7 V – 29 V DC
Size and weight
Operating Current Range
5 A (Max) in operation (12 V DC)
Size and weight
Energy management (wake-up/standby)
Power-on/off when Ethernet traffic starts/stops (PC or upstream module on/off)
Size and weight
Configurable: "On" when CAN/CAN FD traffic starts
Size and weight
Standby current Range
17 mA (typ.) at 12 V DC
Size and weight
25 mA (max.)
Size and weight
Protection
Reverse polarity protection up to 32 V, overload protection
Size and weight
Interfaces
Size and weight
Gigabit Ethernet
1x 100/1000Base-T (HOST) (incl. IEEE1588 (PTP) TimeSync)
Size and weight
Fast Ethernet[1]
1x XETK ECU interface (incl. IEEE1588 (PTP) TimeSync). Alternatively: 1x 10/100Base-T for connecting measurement and interface modules (incl. ETAS TimeSync.), e. g. ES4xx, ES523, ES6xx
Support of IEEE 1588 (PTP) time synchronization
Size and weight
Gigabit Ethernet[1]
1x 10/100/1000Base-T for connecting measurement and interface modules (incl. IEEE1588 TimeSync)
Size and weight
Automotive Ethernet[1]
3x 100 Base-T1 (OPEN Alliance BroadR-Reach), all of them can be used for BR_XETKs (incl. IEEE1588 (PTP) TimeSync).
Size and weight
Device interfaces
Size and weight
Power Supply
For connected ES4xx/ES6xx Measurement Modules and XETKs
Size and weight
Synchronization
Resolution: 1 μs
Size and weight
Bus interfaces
Size and weight
5 x CAN/CAN FD/ CAN XL , 1 X LIN
Size and weight
CAN/CAN FD
5 independent CAN interfaces: CAN FD or CAN High-Speed, CAN protocols CAN 2.0a and 2.0b, CAN Transceiver: NXP TJA1462 ( signal improvement capability using SIC), CAN: 1Mbit/ sec (Max Speed) 8 Bytes (Payload), CAN FD SIC: 5Mbit/ sec (higher number of nodes and sub-topology), 8Mbit/ sec (point to point connection) 64 Bytes (Payload), CAN XL: 8 Mbit/ sec 2048 Bytes (Payload)
Size and weight
LIN
1 independent interface LIN V2.1, LIN Transceiver: MCZ33661EF
Size and weight
Status displays
Size and weight
LEDs
Status of operation, interfaces and synchronization
Size and weight
Wakeup Management
Size and weight
Standby mode : System automatically switches to standby mode when none of the host ethernet or AE nodes, CAN-FD, CAN and LIN nodes detects any data traffic signal
Size and weight
Wakeup mode : System automatically switches to On mode when either host ethernet or Data traffic or at least one of the AE nodes, CAN-FD, CAN and LIN node detects any data traffic
Size and weight
Compatible hardware
Size and weight
PC/ETAS upstream modules
PC with Ethernet connection, ES820 Drive Recorder
Size and weight
ETAS downstream modules
ES523, ES592, ES593-D, ES595, ES88x Network and Interface Modules; ES4xx, ES6xx Measurement Modules; ES910.3 Prototyping and Interface Module; ES930 Multi-I/O Module or ES600.2
Size and weight
Supported ETAS software
Size and weight
ETAS INCA
Supported onward INCA V7.4.3
Size and weight
Firmware Update
Supported onward HSP V13.7.0
Notes
This product has been developed and released for use in automotive applications. For usage in other domains please contact your ETAS representative.

Downloads

Icon document download

ETAS Download Center provides abundant information on ETAS Products and Solutions, in the form of flyers, brochures, technical articles, or manuals. You will also find hotfixes and software updates.

Contact us

Do you have any questions? Feel free to send us a message. We will be more than happy to help.

Contact us today!