Skip to main content
ES650

ES650 – Thermo and A/D module

ES650 – Thermo and A/D Module

The ES650 measures temperatures and analog input voltages each with 8 channels. All 16 channels are electrically isolated from each other and from the supply voltage to achieve a consistently high common-mode rejection, thus ensuring maximum measurement accuracy even at extremely low voltages and non-potential-free thermocouples.

A separate ice point reference at each input connector significantly minimizes the measurement error, even when ambient temperatures are fluctuating. The ES650 supports type B, E, J, K, N, R, S, and T thermocouples covering a measuring range of -210°C to +1820°C (-346°F to +3308°F). The module operates at a resolution of 21 bit over the entire range, which allows a minimum measurement unit of 0.01°C with a basic accuracy of +0.25°C (K type). At a resolution of 16 bit, two selectable measuring ranges are available for high precision voltage measurements. The ES650 reaches a basic voltage measurement accuracy of up to 2 mV. To maintain the high precision even at large fluctuations of the ambient temperature, the measuring module has an ultra-low temperature coefficient of only 10 ppm/°C. To avoid capturing redundant data, the ES650 allows the software filter and sampling rate to be optimized individually for each module.

Functions at a glance

  • 8 electrically isolated measuring channels for analog voltages
  • 8 electrically isolated measuring channels for temperature sensor types B, E, J, K, N, R, S, T
  • Measuring channels electrically isolated from the supply voltage
  • Adjustable acquisition rate per channel
  • Individual A/D converters per channel and synchronous sampling ensure zero delay between channels
  • Parameterized software filter for signal smoothing
  • High measuring accuracy through 16 bit (A/D) or 21 bit (thermal) resolution
  • Two selectable measuring ranges of +10 V and +60 V
  • Automotive measuring range of -210°C to +1820°C (-346°F to +3308°F)
  • Data transfer to PC or ES600 via Ethernet
  • Rugged, functional metal housing
  • Hardware calibration service

Technical data

Size and Weight
Size and Weight
Dimensions (HxWxD)
72 x 128 x 160 mm / 2.8 x 5 x 6.3 in
Size and Weight
Weight
1085 g / 2.39 lbs
Size and Weight
Environment
Size and Weight
Temperature range
-40 °C to +70 °C / -40 °F to +158 °F (operation)
Size and Weight
-40 °C to +85 °C / -40 °F to +185 °F (storage)
Size and Weight
Power supply
Size and Weight
Operating voltage (reverse voltage protection)
6 V to 32 V DC, reverse-voltage protected up to 40 V, protected against load dump
Size and Weight
Current consumption
Size and Weight
Continuous operation
270 mA at 12 V
Size and Weight
Stand-by
5 mA at 12 V
Size and Weight
Host interface
Size and Weight
Ethernet connection
10 Base-T
Size and Weight
Protocol
TCP/IP
Size and Weight
IP address
Dynamically via INCA
Size and Weight
Inputs
Size and Weight
Number of channels
8
Size and Weight
Resolution
21 bit, corresponding to 0.01 °C
Size and Weight
Acquisition rate
0.1 Samples/s to 10 Samples/s, configurable per module
Size and Weight
Measuring range depending on thermocouple type
B +250 °C to +1820 °C / +482 °F to +3308 °F
Size and Weight
E -200 °C to +1000 °C / -328 °F to +1832 °F
Size and Weight
J -210 °C to +1200 °C / -346 °F to +2192 °F
Size and Weight
K -200 °C to +1372 °C / -392 °F to +2502 °F
Size and Weight
N -200 °C to +1300 °C / -392 °F to +2372 °F
Size and Weight
R -50 °C to +1768 °C / -58 °F to +3214 °F
Size and Weight
S -50 °C to +1768 °C / -58 °F to +3214 °F
Size and Weight
T -200 °C to +400 °C / -392 °F to +752 °F
Size and Weight
Limit frequency
10 Hz
Size and Weight
Input impedance
>10 MΩ II 1 nF
Size and Weight
Maximum inaccuracy ΔTg depending on thermocouple type
B 0.050 % + 5.0 K
Size and Weight
E 0.050 % + 0.2 K
Size and Weight
J 0.030 % + 0.2 K
Size and Weight
K 0.025 % + 0.25 K
Size and Weight
N 0.035 % + 0.38 K
Size and Weight
R 0.050 % + 2.0 K
Size and Weight
S 0.050 % + 2.0 K
Size and Weight
T 0.050 % + 0.3 K
Size and Weight
Maximum temperature drift ΔTd depending on thermocouple type
B ±0.1 K/K
Size and Weight
E ±0.004 K/K
Size and Weight
J ±0.004 K/K
Size and Weight
K ±0.005 K/K
Size and Weight
N ±0.008 K/K
Size and Weight
R ±0.04 K/K
Size and Weight
S ±0.04 K/K
Size and Weight
T ±0.005 K/K
Size and Weight
Maximum inaccuracy ΔTi depending on the internal resistance of the respective thermocouple at internal resistances > 50 Ω
B ±0.08 K/Ω
Size and Weight
E ±0.03 K/Ω
Size and Weight
J ±0.003 K/Ω
Size and Weight
K ±0.004 K/Ω
Size and Weight
N ±0.006 K/Ω
Size and Weight
R ±0.03 K/Ω
Size and Weight
S ±0.03 K/Ω
Size and Weight
T ±0.004 K/Ω
Size and Weight
Maximum inaccuracy of cold junction compensation ΔTcjc
±1 K
Size and Weight
Maximum temperature drift of cold junction compensation ΔTd
±0.008 K/K
Size and Weight
Maximum allowed input voltage
32 V
Size and Weight
Inputs general
Size and Weight
Electrical isolation of inputs
±100 V channel to channel, channel to supply voltage
Size and Weight
A/D inputs
Size and Weight
Number of channels
8
Size and Weight
Resolution
16 bit, higher at slower sampling rates
Size and Weight
Acquisition rate
0.5 Samples/s to 2 kSamples/s, configurable per module
Size and Weight
Input voltage ranges
±10 V, ±60 V
Size and Weight
Input filter
Low-pass of 4th order, limit frequency 1 kHz, max. overshooting 3 %
Size and Weight
Input impedance
>15 MΩ II 1 nF (±10 V); 2 MΩ II 1 nF (±60 V)
Size and Weight
Measurement error
2 mV + (U in x 0.05 %) in the ±10 V measuring range
Size and Weight
12 mV + (U in x 0.05 %) in the ±60 V measuring range
Size and Weight
Temperature drift
10 ppm/°C, relative to input voltage
Size and Weight
Support by ETAS Software
Size and Weight
INCA
Notes
This product has been developed and released for use in automotive applications. For usage in other domains please contact your ETAS representative.

Downloads

Icon document download

ETAS Download Center provides abundant information on ETAS Products and Solutions, in the form of flyers, brochures, technical articles, or manuals. You will also find hotfixes and software updates.

Contact us

Do you have any questions? Feel free to send us a message. We will be more than happy to help.

Contact us today!