Skip to main content
ES620

ES620 – Thermo module

ES620 – Thermo Module

Temperature measurements using a thermocouple means measuring voltage in the microvolt range. The ES620 captures signals from temperature sensors via 16 channels that are electrically isolated from each other and from the supply voltage to achieve a consistently high common-mode rejection. This ensures maximum measuring accuracy even with non-potential-free thermocouples.

A separate ice point reference at each input connector significantly minimizes the measurement error, even when ambient temperatures are fluctuating (e.g., due to strong sunlight). The ES620 supports type B, E, J, K, N, R, S, and T thermocouples covering a measuring range of -210°C to +1820 °C (-346°F to +3308°F). The module operates at a resolution of 21 bit over the entire range, which allows a minimum measurement unit of 0.01°C with a basic accuracy of +0.25°C (K type). Temperature signals often only vary very slowly. A high sampling rate would cause redundant data which again would needlessly strain transfer channels and memory ressources. To avoid this, software filters and sampling rates can be optimized separately for each module.

Functions at a glance

  • 16 electrically isolated measuring channels for temperature sensors
  • Measuring channels electrically isolated from the supply voltage
  • Adjustable acquisition rate per channel; 10 samples/s to 0.1 samples/s
  • Parameterized software filter for signal smoothing
  • High measuring accuracy through 21-bit resolution
  • Automotive measuring range of -210°C to +1820°C (-346°F to +3308°F)
  • Use of B, E, J, K, N, R, S and T thermocouples
  • Data transfer to PC via Ethernet
  • Rugged, functional metal housing
  • Hardware calibration service

Technical data

Size and Weight
Size and Weight
Dimensions (HxWxD)
72 x 128 x 160 mm / 2.8 x 5 x 6.3 in
Size and Weight
Weight
1020 g / 2.25 lbs
Size and Weight
Environment
Size and Weight
Temperature range
-40 °C to +70 °C / -40 °F to +158 °F (operation)
Size and Weight
-40 °C to +85 °C / -40 °F to +185 °F (storage)
Size and Weight
Power supply
Size and Weight
Operating voltage (reverse voltage protection)
6 V to 32 V DC, reverse-voltage protected up to 40 V, protected against load dump
Size and Weight
Current consumption
Size and Weight
Continuous operation
220 mA at 12 V
Size and Weight
Stand-by
5 mA at 12 V
Size and Weight
Host interface
Size and Weight
Ethernet connection
10 Base-T
Size and Weight
Protocol
TCP/IP
Size and Weight
IP address
Dynamically via INCA
Size and Weight
Inputs
Size and Weight
Number of channels
16
Size and Weight
Resolution
21 bit, corresponding to 0.01 °C
Size and Weight
Acquisition rate
0.1 Samples/s to 10 Samples/s, configurable per module
Size and Weight
Measuring range depending on thermocouple type
B +250 °C to +1820 °C / +482 °F to +3308 °F
Size and Weight
E -200 °C to +1000 °C / -328 °F to +1832 °F
Size and Weight
J -210 °C to +1200 °C / -346 °F to +2192 °F
Size and Weight
K -200 °C to +1372 °C / -392 °F to +2502 °F
Size and Weight
N -200 °C to +1300 °C / -392 °F to +2372 °F
Size and Weight
R -50 °C to +1768 °C / -58 °F to +3214 °F
Size and Weight
S -50 °C to +1768 °C / -58 °F to +3214 °F
Size and Weight
T -200 °C to +400 °C / -392 °F to +752 °F
Size and Weight
Limit frequency
10 Hz
Size and Weight
Input impedance
>10 MΩ II 1 nF
Size and Weight
Electrical isolation of inputs
±100 V channel to channel, channel to supply voltage
Size and Weight
Accuracy [1]
Size and Weight
Basic accuracy ΔTg depending on thermocouple type
B ±(0.050 % + 5.0 K)
Size and Weight
E ±(0.050 % + 0.2 K)
Size and Weight
J ±(0.030 % + 0.2 K)
Size and Weight
K ±(0.025 % + 0.25 K)
Size and Weight
N ±(0.035 % + 0.38 K)
Size and Weight
R ±(0.050 % + 2.0 K)
Size and Weight
S ±(0.050 % + 2.0 K)
Size and Weight
T ±(0.050 % + 0.3 K)
Size and Weight
Maximum temperature drift ΔTd depending on thermocouple type
B ±0.1 K/K
Size and Weight
E ±0.004 K/K
Size and Weight
J ±0.004 K/K
Size and Weight
K ±0.005 K/K
Size and Weight
N ±0.008 K/K
Size and Weight
R ±0.04 K/K
Size and Weight
S ±0.04 K/K
Size and Weight
T ±0.005 K/K
Size and Weight
Accuracy ΔTi depending on the internal resistance of the respective thermocouple at internal resistances > 50 Ω
B ±0.08 K/Ω
Size and Weight
E ±0.03 K/Ω
Size and Weight
J ±0.003 K/Ω
Size and Weight
K ±0.004 K/Ω
Size and Weight
N ±0.006 K/Ω
Size and Weight
R ±0.03 K/Ω
Size and Weight
S ±0.03 K/Ω
Size and Weight
T ±0.004 K/Ω
Size and Weight
Accuracy of cold junction compensation ΔTcjc
±1 K
Size and Weight
Maximum temperature drift of cold junction compensation ΔTdcjc
±0.008 K/K
Size and Weight
Inputs
Size and Weight
Maximum allowed input voltage
32 V
Size and Weight
Support by ETAS Software
Size and Weight
INCA
Size and Weight
Notes
Size and Weight
[1]
Total error of a temperature measurement ΔT = ΔTg + ΔTd + ΔTi + ΔTcjc + ΔTdcjc
This product has been developed and released for use in automotive applications. For usage in other domains please contact your ETAS representative.

Downloads

Icon document download

ETAS Download Center provides abundant information on ETAS Products and Solutions, in the form of flyers, brochures, technical articles, or manuals. You will also find hotfixes and software updates.

Contact us

Do you have any questions? Feel free to send us a message. We will be more than happy to help.

Contact us today!