ES620 – Thermo module
Functions at a glance
- 16 electrically isolated measuring channels for temperature sensors
- Measuring channels electrically isolated from the supply voltage
- Adjustable acquisition rate per channel; 10 samples/s to 0.1 samples/s
- Parameterized software filter for signal smoothing
- High measuring accuracy through 21-bit resolution
- Automotive measuring range of -210°C to +1820°C (-346°F to +3308°F)
- Use of B, E, J, K, N, R, S and T thermocouples
- Data transfer to PC via Ethernet
- Rugged, functional metal housing
- Hardware calibration service
Technical data
Size and Weight | |
Size and Weight
Dimensions (HxWxD)
|
72 x 128 x 160 mm / 2.8 x 5 x 6.3 in
|
Size and Weight
Weight
|
1020 g / 2.25 lbs
|
Size and Weight
Environment
|
|
Size and Weight
Temperature range
|
-40 °C to +70 °C / -40 °F to +158 °F (operation)
|
Size and Weight
|
-40 °C to +85 °C / -40 °F to +185 °F (storage)
|
Size and Weight
Power supply
|
|
Size and Weight
Operating voltage (reverse voltage protection)
|
6 V to 32 V DC, reverse-voltage protected up to 40 V, protected against load dump
|
Size and Weight
Current consumption
|
|
Size and Weight
Continuous operation
|
220 mA at 12 V
|
Size and Weight
Stand-by
|
5 mA at 12 V
|
Size and Weight
Host interface
|
|
Size and Weight
Ethernet connection
|
10 Base-T
|
Size and Weight
Protocol
|
TCP/IP
|
Size and Weight
IP address
|
Dynamically via INCA
|
Size and Weight
Inputs
|
|
Size and Weight
Number of channels
|
16
|
Size and Weight
Resolution
|
21 bit, corresponding to 0.01 °C
|
Size and Weight
Acquisition rate
|
0.1 Samples/s to 10 Samples/s, configurable per module
|
Size and Weight
Measuring range depending on thermocouple type
|
B +250 °C to +1820 °C / +482 °F to +3308 °F
|
Size and Weight
|
E -200 °C to +1000 °C / -328 °F to +1832 °F
|
Size and Weight
|
J -210 °C to +1200 °C / -346 °F to +2192 °F
|
Size and Weight
|
K -200 °C to +1372 °C / -392 °F to +2502 °F
|
Size and Weight
|
N -200 °C to +1300 °C / -392 °F to +2372 °F
|
Size and Weight
|
R -50 °C to +1768 °C / -58 °F to +3214 °F
|
Size and Weight
|
S -50 °C to +1768 °C / -58 °F to +3214 °F
|
Size and Weight
|
T -200 °C to +400 °C / -392 °F to +752 °F
|
Size and Weight
Limit frequency
|
10 Hz
|
Size and Weight
Input impedance
|
>10 MΩ II 1 nF
|
Size and Weight
Electrical isolation of inputs
|
±100 V channel to channel, channel to supply voltage
|
Size and Weight
Accuracy [1]
|
|
Size and Weight
Basic accuracy ΔTg depending on thermocouple type
|
B ±(0.050 % + 5.0 K)
|
Size and Weight
|
E ±(0.050 % + 0.2 K)
|
Size and Weight
|
J ±(0.030 % + 0.2 K)
|
Size and Weight
|
K ±(0.025 % + 0.25 K)
|
Size and Weight
|
N ±(0.035 % + 0.38 K)
|
Size and Weight
|
R ±(0.050 % + 2.0 K)
|
Size and Weight
|
S ±(0.050 % + 2.0 K)
|
Size and Weight
|
T ±(0.050 % + 0.3 K)
|
Size and Weight
Maximum temperature drift ΔTd depending on thermocouple type
|
B ±0.1 K/K
|
Size and Weight
|
E ±0.004 K/K
|
Size and Weight
|
J ±0.004 K/K
|
Size and Weight
|
K ±0.005 K/K
|
Size and Weight
|
N ±0.008 K/K
|
Size and Weight
|
R ±0.04 K/K
|
Size and Weight
|
S ±0.04 K/K
|
Size and Weight
|
T ±0.005 K/K
|
Size and Weight
Accuracy ΔTi depending on the internal resistance of the respective thermocouple at internal resistances > 50 Ω
|
B ±0.08 K/Ω
|
Size and Weight
|
E ±0.03 K/Ω
|
Size and Weight
|
J ±0.003 K/Ω
|
Size and Weight
|
K ±0.004 K/Ω
|
Size and Weight
|
N ±0.006 K/Ω
|
Size and Weight
|
R ±0.03 K/Ω
|
Size and Weight
|
S ±0.03 K/Ω
|
Size and Weight
|
T ±0.004 K/Ω
|
Size and Weight
Accuracy of cold junction compensation ΔTcjc
|
±1 K
|
Size and Weight
Maximum temperature drift of cold junction compensation ΔTdcjc
|
±0.008 K/K
|
Size and Weight
Inputs
|
|
Size and Weight
Maximum allowed input voltage
|
32 V
|
Size and Weight
Support by ETAS Software
|
|
Size and Weight
|
INCA
|
Size and Weight
Notes
|
|
Size and Weight
[1]
|
Total error of a temperature measurement ΔT = ΔTg + ΔTd + ΔTi + ΔTcjc + ΔTdcjc
|