Skip to main content
ES600

ES600 – Network module

ES600 – Network Module

The ES600 Network Module is ideally suited for automotive use. It is the heart of the modular, Ethernet-based ETAS measurement, calibration, diagnostics and prototyping system.

Up to six ETAS compact hardware modules – including additional ES600 modules – can be connected to an ES600 Network Module and synchronized and provided with power by it. On top of that, the ES600 modules synchronize the data collected via the individual channels of the connected measurement, interface or prototyping modules.

For example, with the help of the ES600.2 module you can connect up to four ECUs with an XETK interface to the ES910 Prototyping and Interface Module with which, on the test bench, values can be modified in the ECU and measured data acquired in short cycles.

ES600 modules help prevent the periodic divergence of different signals during a measurement: the linked modules act as a single measuring instrument, the timestamps of which fluctuate less than a microsecond from the specified cycle time. This guarantees temporal correlation of the data from different measuring channels at all times.

A series of LEDs continuously display the module’s operating and error status as well as the activity of the individual connections. To save electricity, the connected modules automatically switch to standby mode when no PC or drive recorder is hooked up. To avoid load peaks, the ES600 modules switch on the connected devices sequentially during startup.

Your benefits

  • Data transfer between the host application on the desktop / laptop PC, ES910 Prototyping and Interface Module, and multiple measurement, interface or prototyping modules, or XETK ECU interfaces via Gigabit Ethernet
  • Six Fast Ethernet device ports with integrated power supply
  • Multiple ES600.2 modules can be connected in series
  • Precise time synchronization of all connected measuring channels with a precision of at least 1 μs
  • Standby function
  • Sequential switching-on of connected devices
  • Status display for all devices and data transfers
  • Stable, functional metal housing
Graphic of time synchronization when the ES600 is the master

Time synchronization in a fast ethernet group

The modules provide a global clock pulse for comparing the measurement channels in a module network.

The time synchronization unit of the ES600 master synchronizes the connected modules via the Ethernet lines. The slave modules adapt to the clock rate specified by the master module. The master module is always the module that is connected to the PC.

This excludes the possibility of a phase shift between the individual measurement signals, even when measurements are taken from different modules. The data of all the connected modules from the ES4xx, ES5xx, and ES6xx model ranges and from the (X)ETK is acquired synchronously with microsecond precision.

Option 2: The IEEE1588 signal isn’t being forwarded via the ES600.2. The two IEEE domains are depicted separately on PC.

If an ES89x is expanded with an ES600 module in a test setup, they will communicate with each other via a Gigabit Ethernet connection. In this domain, time synchronization takes place in accordance with the "IEEE 1588" protocol.

The downstream modules connected to the ES600 communicate via an Ethernet connection. The signals are synchronized in this domain in accordance with the "ETAS Sync" protocol. The ES600 serves as an interface between the two domains and ensures that the signals of the downstream modules are nevertheless displayed on the computer synchronously in accordance with the "IEEE 1588" protocol.

The data of all the connected modules from the ES4xx, ES5xx, and ES6xx model ranges and from the (X)ETK is acquired synchronously with microsecond precision.

Time synchronization with the ES89x and BR_XETK

If the (X)ETK is replaced by a BR_XETK in the above-mentioned test setup, the IEEE 1588 signal will not be forwarded via the Fast Ethernet port of the ES600. Instead, the two IEEE domains will be displayed separately on the computer. Within the individual domains, time synchronization will continue to take place with microsecond precision. The two time domains are synchronized by INCA with millisecond precision.

Wake-up and stand-by function

With use inside a vehicle, the energy consumption must be as low as possible, because the measuring equipment is supplied by a battery. For this reason, all the connections on the ES600 module are equipped with a link signal detector for an automatic electric power saving function.

The wake-up and stand-by function enables the module to switch automatically between the "Standby" and "On" operating states.

The ES600 and any ETAS modules connected to it will automatically switch to the "Standby" operating state if none of the connections receive link signals any longer or if the ES8xx or host computer is switched off or disconnected. As soon as link signals are received on at least one of the connections or the ES8xx or host computer is activated again, the module will automatically switch from standby to the "On" operating state and will automatically switch on connected ETAS modules in the measuring system.

Technical data

Size and Weight
Size and Weight
Dimensions (HxWxD)
36 mm x 127 mm x 160 mm / 1.4 in x 5 in x 6.3 in
Size and Weight
Weight
0.64 Kg / 1.42 lbs
Size and Weight
Environment
Size and Weight
Temperature range
-40°C to +70°C / -40 °F to +158 °F (Operation)
Size and Weight
-40 °C to +85 °C / -40 °C to +185 °F (storage)
Size and Weight
Humidity (not condensing)
0 % - 85 % (operation)
Size and Weight
0 % - 95 % (storage)
Size and Weight
Operating Current Range
14 A (Max.)
Size and Weight
Protection class
IP40
Size and Weight
Power supply
Size and Weight
Operating voltage
7 V to 29 V DC
Size and Weight
Current consumption
(without power supply of connected devices)
Continuous operation < 300 mA at 14.4 V; standby < 60 mA at 14.4 V
Size and Weight
Energy management
"On/ off" at start/ stop of the Ethernet communication (on/ off upstream module)
Size and Weight
Protection
Reverse-voltage protected up to 32 V, protected against load dump
Size and Weight
Host interface
Size and Weight
1 x Fast Ethernet connection
10/100 Base-T
Size and Weight
1 x Gigabit Ethernet connection
100/1000 Base-T
Size and Weight
Downstream module interface
Size and Weight
6 x Ethernet connection
10/100 Base-T
Size and Weight
Power supply of connected modules
2 A per interface, with current limitation
Size and Weight
Synchronization
Resolution: 1 μs
Size and Weight
Status indication
Size and Weight
Module status
1 x Green/Red LED
Size and Weight
Downstream communication
1 x Green/Red LED for each connection
Size and Weight
Host connection
1 x Green LED for each Host
Size and Weight
Compatible hardware
Size and Weight
PC/ETAS upstream modules
Desktop- or laptop-PC with Ethernet connector, ES51x, ES592, ES593-D, ES595, ES600, ES800 [1] Network and Interface Modules, Prototyping and Interface Module ES910
Size and Weight
ETAS downstream modules
ECU with XETK- or generic Ethernet interface, ES51x, ES590/ES591 [1], ES592, ES593-D, ES595 Network and Interface Modules, ES4xx and ES6xx Measurement Modules, ES910 Prototyping and Interface Module, BR_XETK with Media Converter Cable CBEB100
Size and Weight
ETAS Software
Size and Weight
Hardware Service Pack (HSP)
Firmware updates for the ES600.2 module are provided up from HSP V10.9.0
Notes
[1]not synchronized
This product has been developed and released for use in automotive applications. For usage in other domains please contact your ETAS representative.

Downloads

Icon document download

ETAS Download Center provides abundant information on ETAS Products and Solutions, in the form of flyers, brochures, technical articles, or manuals. You will also find hotfixes and software updates.

Contact us

Do you have any questions? Feel free to send us a message. We will be more than happy to help.

Contact us today!