Skip to main content
ES584

ES584 – USB CAN FD and LIN bus interface module

 ES584 – USB CAN FD and LIN bus interface module

Compact and cost-effective, the ES584 interface features CAN FD and LIN bus channels. The module connects CAN FD and LIN buses or vehicle ECUs to a PC or laptop by USB, with the PC or laptop serving as the power supply. After the drivers have been installed, connection and configuration of the module are as straightforward as a typical USB installation.

The ES584 module can record measurement data via the CAN FD and LIN interface. This information is synchronized with the signals from other ECUs and measurement modules in INCA with great precision. In conjunction with the INCA software, the ES584 module can moreover be used to calibrate ECU parameters, program flash memory, and run diagnostics of vehicle electronics.

CAN FD

CAN FD (CAN with flexible data rate) is an improved, backward-compatible CAN protocol developed by BOSCH. It differs from CAN mainly as regards the increase of payload data per message from 8 to 64 bytes, higher transfer rates of up to 8 Mbit/s, and longer verification checks which, in turn, increase the reliability of the transfer. CAN FD satisfies the automobile industry’s demand for networks with higher bandwidths. At the same time, CAN FD nodes can be easily integrated into existing CAN infrastructure.

Your benefits

  • Supports ISO-compliant and non-ISO-compliant version of the CAN FD protocol
  • LIN support for master and slave mode
  • Y-cable for simultaneous connection of the CAN FD and LIN channels included
  • Simple and direct connection to the host computer via USB interface
  • Optimized for flash programming, recording measurement data, calibration, and diagnostics for ECUs
  • Fully compatible with INCA
  • Galvanic isolation of CAN-FD and LIN interfaces from the host computer offers protection from high voltage

With its support for CAN FD, the ES584 module is a suitable tool for a number of applications in both the conventional CAN and the CAN FD environments. For example, it can be connected to a vehicle CAN via the diagnostics service port. The module supports all protocols used by INCA, such as CCP, XCP, KWP-on-CAN, and UDS, although the CCP and KWP-on-CAN (ISO14230/ISO15765) protocols are supported in the conventional CAN mode only.

The ES584 module’s LIN interfaces can be operated in slave or master mode.

For validating vehicle diagnostics, the module can be used in conjunction with ODX-LINK, the INCA add-on for ECU diagnostics, as an interface for OBD-on-CAN and for reading and removing diagnostic trouble codes (DTCs). In such cases, a separate diagnostic service tool is not required. The ES584 module provides an open SAE-J2534-compliant pass-thru interface for vehicle diagnostics and flash programming.

Technical data

Size and Weight
Size and Weight
Dimensions (HxWxD)
23 mm x 45 mm x 87 mm / 0.91 in x 1.77 in x 3.43 in (housing)
Size and Weight
Length of the integrated USB cable
1,5 m / 4.92 ft
Size and Weight
Weight
150 g / 5.291 oz (with cable)
Size and Weight
Environment
Size and Weight
Temperature range
-40 °C to +70 °C / -40 °F to +158 °F (operation)
-40 °C to +85 °C / -40 °F to +185 °F (transport and storage)
Size and Weight
Relative humidity range
15 % to 95 %, non-condensing
Size and Weight
Power supply
Size and Weight
Power consumption
Power provided by USB port of the host PC or notebook
Size and Weight
CAN/CAN-FD interface
Size and Weight
Number of channels
1
Size and Weight
Mode of operation
CAN or CAN FD operation for the CAN FD Port can be individually configured in the software
Size and Weight
Support for CAN FD variants
In CAN FD mode, the protocol variant ISO/non-ISO for the CAN FD channel can be configured in the software
Size and Weight
Protocols for CAN/CAN FD
XCP, UDS (ISO 14229/ISO 15765), CAN Monitoring, OBD-on-CAN (ISO 15765-4)
Size and Weight
Protocols for CAN
CCP, KWP-on-CAN (ISO 14230/ISO 15765)
Size and Weight
CAN Transceiver (physical layer)
TJA1044G
Size and Weight
Maximum baud rate on CAN
1 Mbit/s
Size and Weight
Maximum baud rate on CAN-FD
5 Mbit/s (Higher baud rates are possible under optimum environmental and topology conditions)
Size and Weight
Electrical isolation
Interface is electrically isolated
Size and Weight
LIN interface
Size and Weight
Number of channels
1
Size and Weight
LIN version
2.1
Size and Weight
Mode of operation
Master/slave
Size and Weight
Electrical isolation
Interface is electrically isolated
Size and Weight
Synchronous data acquisition
Size and Weight
INCA synchronizes the data with signals from measurment modules (for example, from ES4xx or ES6xx modules) and ECUs with ETK or XETK interfaces that have been acquired using the ES584 module
Size and Weight
PC interface
Size and Weight
USB
USB 2.0, High Speed
Size and Weight
Host system requirements
Size and Weight
Operating system
Windows® 7, Windows® 8 , Windows® 10
Size and Weight
Status display
Size and Weight
LEDs
Operating state, interfaces
Size and Weight
Software support
Size and Weight
ETAS INCA V7.2 or higher, ETAS ODX-LINK and ETAS ODX-FLASH V7.2 or higher, ETAS HSP V11.6.0 or higher, BUSMASTER
Size and Weight
Delivery content
Size and Weight
USB CAN FD and LIN bus interface ES584, Y-CAN cable,
CD with driver installations and user manual
Notes
This product has been developed and released for use in automotive applications. For usage in other domains please contact your ETAS representative.