Skip to main content
ES430 / ES432

ES430 / ES432 – Lambda modules

ES432 is a Lambda Module

The ES430 and ES432 Lambda Modules are capable of withstanding the environmental conditions which are typical for exhaust system installations.

The ES430 and ES432 modules facilitate lambda measurement in combination with the Bosch Lambda Sensors LSU 4.9 (ES430/ES432) and LSU ADV-G (ES432). The modules automatically detect the type of sensor connected and set all necessary parameters.

To provide for reliable measurements, ES430/ES432 operates the connected sensor at constant temperature. Based on the raw sensor signals, ES430/ES432 calculates lambda (λ) values as well as 1/λ, air-fuel ratio (A/F), fuel-air ratio (F/A), and oxygen content (O2) in physical representation. The sampling rate of the signal is in the range of 0.5 Hz and 2 kHz. To feed analog post-processing for example at test beds ES430/ES432 provides an electrically isolated analog output. Sampling rate and analog output are software configurable.

To prevent damage or degradation of the sensor element, ES430/ES432 continues heating the sensor ceramics when the modules enter the stand-by mode by disconnecting the host.

To prevent applying wrong characteristic parameters to a sensor, the sensor type is automatically detected via the sensor cable or the sensor itself (LSU ADV-G).

Your benefits

  • Operates one oxygen wideband sensor
  • ES430/ES432 support sensors of type LSU 4.9
  • ES432 supports LSU ADV-G sensors
  • Measures lambda, 1/lambda, air-fuel ratio, fuel-air ratio, oxygen content, and pump current
  • Configurable fast analog output of measurements including linearization
  • Adaptation to different fuel or combustion types by characteristic curves
  • Detection of sensor or wiring failures
  • Operating temperature from -40 °C to 120 °C (-40 °F to 248 °F)
  • Rugged waterproof and dustproof housing (IP67)

Technical data

Size and Weight
Size and Weight
Dimensions (HxWxD)
51 x 40 x 139 mm / 2.0 x 1.6 x 5.5 in
Size and Weight
37 x 40 x 124 mm / 1.5 x 1.6 x 4.9 in (tapered rear)
Size and Weight
Weight
350 g / 0.77 lb
Size and Weight
Environment
Size and Weight
Temperature range
-40 °C to +120 °C (-40 °F to +248 °F) (operation)
Size and Weight
-40 °C to +125 °C (-40 °F to +257 °F) (storage)
Size and Weight
Protection class
IP67 (with cables connected)
Size and Weight
Altitude
Up to 5,000 m / 16,400 ft
Size and Weight
Tested for
Mechanical shock, vibration, fall, temperature shock, temperature alteration, storage in humidity, salt fog attack, impact from flying rocks, according to DIN EN 60068 res. ISO 16750
Size and Weight
Power Supply (module)
Size and Weight
Operating voltage
5 V to 50 V DC (-40 °C to +85 °C / -40 °F to +185 °F),
Size and Weight
6 V to 50 V DC (+85 °C to +120 °C / +185 °F to +248 °F)
Size and Weight
Reverse voltage protection; Load dump protection
Via Cables CBEP410 / 415 / 425 / 430 / 450
Size and Weight
Power consumption (at 12 V)
2.0 W typ. (operation), < 200 mW (stand-by)
Size and Weight
Power Supply (sensor heater)
Size and Weight
Reverse voltage protection; Load dump protection
Via Lambda Sensor Cables
Size and Weight
Operating voltage
9 V to 16 V
Size and Weight
Maximum voltage
28 V
Size and Weight
Host interface
Size and Weight
Ethernet connection
100 Base-T
Size and Weight
Protocol
XCP-on-UDP/IP
Size and Weight
IP address
Dynamic via INCA or ES400 configuration and integration tool (default 192.168.40.44)
Size and Weight
Measurement signal types (signals can be provided concurrently to host system for each input channel)
Lambda, 1/ Lambda, A/F, F/A, O2 , or Ip; software
configurable
Size and Weight
Sensor connection
Size and Weight
Channels
1
Size and Weight
Supported sensor types
BOSCH LSU4.9 (ES430/ES432) or LSU ADV-G (ES432)
Size and Weight
Sensor detection via sensor
LSU ADV-G with trapezoid plug, code A7
Size and Weight
Sensor detection via splitter cable
LSU 4.9 with RB150 plug, code 1 or code A
Size and Weight
Sampling rate
0.5 Samples/s to 2 kSamples/s, Ri is measured with 2 Samples/s
Size and Weight
Heater control
Included; configurable to keep sensor in operation also in module stand-by mode
Size and Weight
Measurement range
λ: 0.6 to 16
Size and Weight
1/λ: 1.67 to 0.0625
Size and Weight
A/F: 8.5 to 200
Size and Weight
F/A: 0.118 to 0.005
Size and Weight
O2: 0 % to 25 %
Size and Weight
Ip: -2.5 mA to 5 mA
Size and Weight
Ri: 0 Ω to 1950 Ω
Size and Weight
Analog output
Size and Weight
Channels
1, electrically isolated to any supply
Size and Weight
Range
0 to 10 V
Size and Weight
Signal types
λ, 1/λ, A/F, F/A, O2 , or Ip, configurable via software
Size and Weight
Output impedance
Virtually 0 Ω, short-circuit proof and protected against external voltage of up to 28 V
Size and Weight
Support by ETAS Software
Size and Weight
Supported by INCA V5.4.1 and up (ES430), by INCA 6.2.1 and up (ES432) via add-on (part of ES430/ES432 delivery), INTECRIO V3.x, ES400 configuration and integration tool for XCP applications
Notes
This product has been developed and released for use in automotive applications. For usage in other domains please contact your ETAS representative.

Downloads

Icon document download

ETAS Download Center provides abundant information on ETAS Products and Solutions, in the form of flyers, brochures, technical articles, or manuals. You will also find hotfixes and software updates.

Contact us

Do you have any questions? Feel free to send us a message. We will be more than happy to help.

Contact us today!