ES415 – High definition A/D module with sensor supply
Your benefits
- Fast start-up with no additional hardware
- Efficient measurement data acquisition via Ethernet without restriction of data transfer at high sampling rates
- Easy integration into existing measurement systems by using standardized XCP protocols for measurement data transfer and calibration as well as the UDP protocol for network communication
- The robust design ensures reliable use under extreme conditions
- Flexible connection of various sensors and measurement transducers via a standardized interface
- Automatic measurement data synchronization when working together with other ETAS measuring modules
- Measurement data acquisition and analysis using professional software solutions such as INCA and MDA
Functions at a glance
- 4 electrically isolated channels, separately configurable
- Measurement range between 100 mV and 60 V
- Measurement adapters for measurement range extension are available
- Data acquisition rates between 0.5 Hz and 100 kHz, separately adjustable for each channel
- Low-pass filters for optimum signal conditioning
- Adjustable and short circuit proof sensor supply voltage between 5 V and 15 V
- Automatic detection and configuration of sensors with TEDS (Transducer Electronic Data Sheet)
- Robust, water- and dust-tight housings and connections (IP67)
- Operating temperature -40 °C to 120 °C (-40 °F to 248 °F)
Technical data
Size and Weight | |
Size and Weight
Dimensions (HxWxD)
|
52 x 40 x 142 mm / 2.0 x 1.6 x 5.6 in (total)
39 x 40 x 63 mm / 1.5 x 1.6 x 2.5 in (tapered rear) |
Size and Weight
Weight
|
350 g / 0.77 lb
|
Size and Weight
Environment
|
|
Size and Weight
Temperature range
|
-40 °C to +120 °C (-40 °F to +248 °F) (operation)
-40 °C bis +125 °C (storage) |
Size and Weight
Protection class
|
IP67
|
Size and Weight
Altitude
|
Deployable up to 5,000 m /16,400 ft
|
Size and Weight
Tested for
|
Mechanical shock, vibration, fall, temperature shock, temperature alteration, storage in humid-ity, salt fog attack, impact from flying rocks, according to DIN EN 60068 res. ISO 16750
|
Size and Weight
Power supply
|
|
Size and Weight
Operating voltage
|
5 V to 50 V DC (-40 °C to +85 °C / -40 °F to +185 °F),
6 V to 50 V DC (+85 °C to +120 °C / +185 °F to +248 °F) |
Size and Weight
Power consumption (at 12 V)
|
2 W typ. (operation)
6 W max. (operation with max. sensor supply) 25 mW max. (standby) |
Size and Weight
Reverse voltage protection, load dump protection
|
Via cables CBEP410 / 415 / 420 / 425 / 430 / 450
|
Size and Weight
Host interface
|
|
Size and Weight
Ethernet connection and protocol
|
100 Base-T, Full-Duplex required, XCP-on-UDP/IP
|
Size and Weight
IP address
|
192.168.40.44 (Default), configurable via INCA or ES400 configuration and integration tool for XCP applications
|
Size and Weight
Inputs
|
|
Size and Weight
Channels
|
4, with separate sensor supply
|
Size and Weight
Input measurement ranges (MR)
|
± 100 mV, ± 1 V, ± 10 V, ± 60 V
|
Size and Weight
Sampling rate
|
0.5 Samples/s to 100,000 Samples/s, configurable per channel
|
Size and Weight
Anti-aliasing filter (in hardware)
|
Low-pass 4th order Butterworth, 50 kHz corner frequency
|
Size and Weight
Digital filter (Software)
|
Low-pass 2nd order CIC (moving average)
|
Size and Weight
Overvoltage protection [1]
|
±100 V (Input to external overvoltage)
|
Size and Weight
Maximum isolation voltage [1]
|
100 V DC (Input to input or input to supply voltage ground or housing)
|
Size and Weight
Input impedance
|
> 2 MΩ II < 400 pF (± 10 V, ± 60 V)
> 10 MΩ II < 300 pF ( ± 1 V, ± 100 mV) |
Size and Weight
Accuracy
|
|
Size and Weight
Resolution
|
3,6 μV (MB: ± 100 mV)
37,2 μV (MB: ± 1 V) 366 μV (MB: ± 10 V) 2,16 mV (MB: ± 60 V) |
Size and Weight
Measurement error
|
± (100 μV + |Uin| * 0,1%) (MB. ± 100 mV)
± (500 μV + |Uin| * 0,05%) (MB: ± 1 V) ± (3 mV + |Uin| * 0,05%) (MB: ± 10 V) ± (16 mV + |Uin| * 0,2%) (MB: ± 60 V) |
Size and Weight
Temperature drift (-40 °C bis 85 °C)
|
8 μV/K (MB: ± 100 mV)
8 μV/K (MB: ± 1 V) 36 μV/K (MB: ± 10 V) 3,6 mV/K (MB: ± 60 V) |
Size and Weight
Temperature drift (85 °C bis 120 °C)
|
150 μV/K (MB: ± 100 mV)
150 μV/K (MB: ± 1 V) 360 μV/K (MB: ± 10 V) 3,6 mV/K (MB: ± 60 V) |
Size and Weight
Sensor supply output
|
|
Size and Weight
Output voltage
|
0 V, 5 V to 15 V DC, individually configurable per channel
|
Size and Weight
Accuracy of output voltage
|
± 10 mV
|
Size and Weight
Output current
|
30 mA max. per channel
|
Size and Weight
Diagnostics
|
Overload warning by LED and in the software
|
Size and Weight
Support by ETAS Software
|
|
Size and Weight
|
Supported by INCA V7.0 and higher, ES400 configuration and integration tool for XCP applications V1.4.0 and higher, ASCET-RP V6.1.3 and higher, INTECRIO Integration Platform V4.2 and higher, INTECRIO-RLINK V1.0 and higher, HSP Update-Tool V10.0.0 and higher
|
Size and Weight
System requirements
|
|
Size and Weight
|
Computer with Dual-Core I5 or similar, 2,5 GHz, built-in gigabit network controller
|
[1] 60 V maximum for use inside the US.
This product has been developed and released for use in automotive applications. For usage in other domains please contact your ETAS representative.
Contact us
Do you have any questions? Feel free to send us a message. We will be more than happy to help.
Contact us today!