Skip to main content
ES413

ES413 – Eco A/D module with sensor supply

ES413 – Eco A/D Module with Sensor Supply

The ES413 measurement module includes an analog-digital converter for measuring analog signals from sensors or measurement transducers. As Eco model of the ES400 series it combines modern and reliable technology with high efficiency.

4 electrically isolated measurement channels with adjustable and short circuit proof sensor supply are available for measurement.

The integrated sensor connecting cables allow installing the module even in areas which are difficult to access. They are optionally available with proven LEMO connectors or with open ends for flexible adaption to existing systems.

Like all modules of the ES400 series, the ES413 module has a small form factor and is equipped with practical mounting possibilities. Due to its robust design, it also works very reliably even under extreme operating conditions such as in the engine compartment of test vehicles.

Your benefits

  • Fast start-up with no additional hardware
  • Efficient measurement data acquisition via Ethernet without restriction of data transfer at high sampling rates
  • Easy integration into existing measurement systems by using standardized XCP protocols for measurement data transfer and calibration as well as the UDP protocol for network communication
  • The robust design ensures reliable use under extreme conditions
  • Direct connection of the sensors using permanently installed sensor connecting cables allows the space-saving installation of the module in areas that are difficult to access
  • Automatic measurement data synchronization when working together with other ETAS measuring modules
  • Measurement data acquisition and analysis using professional software solutions such as INCA and MDA

Functions at a glance

  • 4 electrically isolated channels, separately configurable
  • Measurement range between 100 mV and 60 V
  • Data acquisition rates between 0.5 Hz and 2 kHz, separately adjustable for each channel
  • Configurable low-pass filters for optimum signal conditioning
  • Adjustable and short circuit proof sensor supply voltage 5 V, 8 V, 10 V, 12V, 15 V
  • Robust, water- and dust-tight housings and connections (IP65)
  • Operating temperature -40 °C to 120 °C (-40 °F to 248 °F)

Technical data

Size and Weight
Size and Weight
Dimensions (HxWxD)
52 x 40 x 145 mm / 2.0 x 1.6 x 5.5 in (total)
39 x 40 x 63 mm / 1.5 x 1.6 x 2.5 in (tapered rear)
Size and Weight
Weight
410 g / 0.90 lb (ES413.1-OW)
Size and Weight
Lengths of sensor connection cables
2x 120 mm / 4.72 in and 2x 220 mm / 8.67 in (ES413.1-OW)
Size and Weight
2x 150 mm / 5.91 in and 2x 250 mm / 9.84 in (ES413.1-L1B, ES413.1-L0B)
Size and Weight
Environment
Size and Weight
Temperature range
-40 °C to +120 °C (-40 °F to +248 °F) (operation)
-40 °C bis +125 °C (storage)
Size and Weight
Protection class
IP65
Size and Weight
Altitude
Deployable up to 5,000 m /16,400 ft
Size and Weight
Power supply
Size and Weight
Operating voltage
5 V to 50 V DC (-40 °C to +85 °C / -40 °F to +185 °F),
6 V to 50 V DC (+85 °C to +120 °C / +185 °F to +248 °F)
Size and Weight
Power consumption (at 12 V)
2 W typ. (operation without sensor supply)
4.6 W max. (operation without max. sensor supply)
25 mW max. (Standby)
Size and Weight
Reverse voltage protection, load dump protection
Via cables CBEP410 / 415 / 420 / 425 / 430 / 450
Size and Weight
Host interface
Size and Weight
Ethernet connection and protocol
100 Base-T, Full-Duplex required, XCP-on-UDP/IP
Size and Weight
IP address
192.168.40.44 (default), configurable via INCA or ES400 configuration and integration tool for XCP applications
Size and Weight
Inputs
Size and Weight
Channels
4, with separate sensor supply
Size and Weight
Input measurement ranges (MR)
± 100 mV, ± 1 V, ± 10 V, ± 60 V
Size and Weight
Sampling rate
0,5 Samples/s to 2000 Samples/s, configurable per channel
Size and Weight
Anti-aliasing filter (in hardware)
Low-pass 4th order Butterworth, 10 kHz corner frequency,
bypass possible
Size and Weight
Digital filter (Software)
Low-pass 8th order Butterworth, 1 kHz corner frequency, bypass possible
Size and Weight
Overvoltage protection [1]
±100 V (Input to external overvoltage)
Size and Weight
Maximum isolation voltage [1]
100 V DC (Input to input or input to supply voltage ground or housing)
Size and Weight
Input impedance
> 2 MΩ II < 400 pF (± 10 V, ± 60 V)
> 10 MΩ II < 300 pF ( ± 1 V, ± 100 mV)
Size and Weight
Accuracy
Size and Weight
Resolution
3,6 μV (MR ± 100 mV)
37,2 μV (MR: ± 1 V)
366 μV (MR: ± 10 V)
2,16 mV (MR: ± 60 V)
Size and Weight
Measurement error
± (200 μV + Vin * 0,12 %) (MR: ± 100 mV)
± (1 mV + Vin * 0,1 %) (MR: ± 1 V)
± (6 mV + Vin * 0,1 %) (MR: ± 10 V)
± (36 mV + Vin * 0,22 %) (MR: ± 60 V)
Size and Weight
Temperature drift (-40 °C bis 85 °C)
16 μV/K (MR: ± 100 mV)
16 μV/K (MR: ± 1 V)
70 μV/K (MR: ± 10 V)
7,2 mV/K (MR: ± 60 V)
Size and Weight
Temperature drift (85 °C bis 120 °C)
300 μV/K (MR: ± 100 mV)
300 μV/K (MR: ± 1 V)
70 μV/K (MR: ± 10 V)
7,2 mV/K (MR: ± 60 V)
Size and Weight
Sensor supply output
Size and Weight
Output voltage
0 V, 5 V, 8 V, 10 V, 12 V, 15 V DC, individually configurable per channel
Size and Weight
Accuracy of output voltage
± 10 mV
Size and Weight
Output current
30 mA max. per channel, protection against overcurrent > 200 mA
Size and Weight
Protection
Outputs (positive) short-circuit protected to ground and up to 26 V overvoltage. Mass is associated with operating voltage ground and protected by a fuse.
Size and Weight
Diagnostics
None
Size and Weight
Support by ETAS Software
Size and Weight
Supported by INCA V6.2.1 and higher, INCA-Add-on V1.1.12 and higher, ES400 configuration and integration tool for XCP applications V1.1.12 and higher, HSP Update-Tool V1.1.12 and higher, INTECRIO V3.2 and higher, ASCET-RP V6.1.0 and higher
Notes
[1] 60 V maximum for use inside the US.
This product has been developed and released for use in automotive applications. For usage in other domains please contact your ETAS representative.