ES411 – A/D module with sensor supply
Benefits
- 4 electrically isolated A/D channels
- Input voltage range between 100 mV and 60 V
- Sampling rate between 0.5 Hz and 10 kHz
- Software configurable high-order low-pass filter
- Sensor supply voltages between 5 V and 15 V
- Short-circuit detection
- Transducer Electronic Data Sheet (TEDS) support
- Configurable per channel
- Operating temperature from -40 °C and 120 °C (-40 °F to 248 °F)
- Rugged water and dustproof housing (IP67)
Technical data
Size and Weight | |
Size and Weight
Dimensions (HxWxD)
|
51.5 x 40 x 142 mm / 2.0 x 1.6 x 5.6 in
37.5 x 40 x 129 mm / 1.5 x 1.6 x 5.1 in (tapered rear) |
Size and Weight
Weight
|
350 g / 0.77 lb
|
Size and Weight
Environment
|
|
Size and Weight
Temperature range
|
-40 °C to +120 °C (-40 °F to +248 °F) (operation)
-40 °C to +125 °C (-40 °F to +257 °F) (storage) |
Size and Weight
Protection class
|
IP67 (with cables connected)
|
Size and Weight
Altitude
|
Up to 5,000 m /16,400 ft
|
Size and Weight
Tested for
|
Mechanical shock, vibration, fall, temperature shock, temperature alteration, storage in humid-ity, salt fog attack, impact from flying rocks, according to DIN EN 60068 res. ISO 16750
|
Size and Weight
Power supply
|
|
Size and Weight
Operating voltage
|
5 V to 50 V DC (-40 °C to +85 °C / -40 °F to +185 °F),
6 V to 50 V DC (+85 °C to +120 °C / +185 °F to +248 °F) |
Size and Weight
Power consumption (at 12 V)
|
1.8 W typ. (operation without load),
< 25 mW (stand-by) |
Size and Weight
Reverse voltage protection; Load dump protection
|
Via Cables CBEP410 / 415 / 420/ 430 / 450
|
Size and Weight
Host interface
|
|
Size and Weight
Ethernet connection and protocol
|
100 Base-T, Full-Duplex required, XCP-on-UDP/IP
|
Size and Weight
IP address
|
Dynamic via INCA or configuration tool (default 192.168.40.44)
|
Size and Weight
Inputs
|
|
Size and Weight
Channels
|
4, each with separate sensor supply
|
Size and Weight
Input measurement ranges (MR)
|
±100 mV, ±1 V, ±10 V, ±60 V for diff. input voltage Vin
|
Size and Weight
Over voltage protection
|
±100 V continuous, all MR
|
Size and Weight
Sampling rate
|
0.5 Samples/s to 10 kSamples/s, configurable per channel [1]
|
Size and Weight
Resolution
|
16 bit
|
Size and Weight
Anti-aliasing filter (in hardware)
|
4th order Butterworth, 10 kHz corner frequency
|
Size and Weight
Software filter[1]
|
Digital FIR Butterworth 8th order, bypass possible, 5 kHz max. corner frequency
|
Size and Weight
Electrical isolation of inputs
|
Channel to channel and channel to supply
|
Size and Weight
Maximum common mode voltage
|
±(100 V - [Vin]) channel to supply ground [1],
Vin ≤±60 V |
Size and Weight
Input impedance
|
> 2 MΩ II < 400 pF (±10 V, ±60 V)
> 10 MΩ II < 300 pF ( ±1 V, ±100 mV) |
Size and Weight
Sensor supply output
|
|
Size and Weight
Output voltage
|
+5 V to +15 V DC or Off, individually adjustable per channel, common ground with power supply, resolution < 1 mV
|
Size and Weight
Output current
|
≤30 mA per channel, overcurrent protected (200 mA)
|
Size and Weight
Accuracy
|
|
Size and Weight
Ripple of output voltage
|
< 10 mV peak to peak
|
Size and Weight
Accuracy of output voltage
|
±10 mV over the whole output voltage range
|
Size and Weight
Measurement Error (MR: 100 mV)
|
±[0.1 % + 80 ppm/K x |T - 25 °C|] x MR ±0.1 % x Vin
|
Size and Weight
Measurement Error (MR: 1 V)
|
±[0.05 % + 8 ppm/K x |T - 25 °C|] x MR ±0.05 % x Vin
|
Size and Weight
Measurement Error (MR: 10 V)
|
±[0.03 % + 3.6 ppm/K x |T -25 °C|] x MR ±0.05 % x Vin
|
Size and Weight
Measurement Error (MR: 60 V)
|
±[0.03 % + 60 ppm/K x |T - 25 °C|] x MR ±0.2 % x Vin
|
Size and Weight
Support by ETAS Software
|
|
Size and Weight
|
Supported by INCA V5.3 and higher, INTECRIO V3.0 and higher, ES400 configuration and integration tool for XCP applications
|
Size and Weight
Notes
|
|
Size and Weight
[1]
|
60 V maximum for use inside the US.
|
Contact us
Do you have any questions? Feel free to send us a message. We will be more than happy to help.
Contact us today!