Your benefits
- 8 electrically isolated A/D (analog input) channels
- Input voltage range between ±100 mV and ±60 V
- Sampling rates between 0.5 Hz and 10 kHz
- Software configurable high-order low-pass filter
- Operating temperature between -40 °C and 120 °C (-40 °F and 248 °F)
- Rugged water and dustproof housing (IP67)
- Cost effective
Technical data
Size and Weight | |
Size and Weight
Dimensions (HxWxD)
|
51.5 x 40 x 142 mm / 2.0 x 1.6 x 5.6 in
37.5 x 40 x 129 mm / 1.5 x 1.6 x 5.1 in (tapered rear) |
Size and Weight
Weight
|
350 g / 0.77 lb
|
Size and Weight
Environment
|
|
Size and Weight
Temperature range
|
-40 °C to +120 °C (-40 °F to +248 °F) (operation)
|
Size and Weight
|
-40 °C to +125 °C (-40 °F to +257 °F) (storage)
|
Size and Weight
Protection class
|
IP67 (with cables connected)
|
Size and Weight
Altitude
|
Up to 5,000 m / 16,400 ft
|
Size and Weight
Tested for
|
Mechanical shock, vibration, fall, temperature shock, temperature alteration, storage in humidity, salt fog attack, impact from flying rocks, according to DIN EN 60068 res. ISO 16750
|
Size and Weight
Power supply
|
|
Size and Weight
Operating voltage
|
5 V to 50 V DC (-40 °C to +85 °C / -40 °F to +185 °F),
|
Size and Weight
|
6 V to 50 V DC (-40 °C to +120 °C / -40 °F to +248 °F)
|
Size and Weight
Power consumption (at 12 V)
|
2.1 W typ., < 25 mW (stand-by)
|
Size and Weight
Reverse voltage protection; Load dump protection
|
Via Cables CBEP410 / 415 / 420 / 430 / 450, CBE400
|
Size and Weight
Host interface
|
|
Size and Weight
Ethernet connection and protocol
|
100 Base-T, Full-Duplex required, XCP-on-UDP/IP
|
Size and Weight
IP address
|
Dynamic via INCA or configuration tool
|
Size and Weight
|
(default 192.168.40.44)
|
Size and Weight
Inputs
|
|
Size and Weight
Channels
|
8
|
Size and Weight
Input measurement ranges (MR)
|
±100 mV, ±1 V, ±10 V, ±60 V for differential input voltage Vin
|
Size and Weight
Over voltage protection
|
±100 V continuous, all MR
|
Size and Weight
Resolution
|
16 bit
|
Size and Weight
Sampling rate
|
0.5 Samples/s to 10 kSamples/s, configurable per channel
|
Size and Weight
Anti-aliasing filter (in hardware)
|
4th order Butterworth, 10 kHz corner frequency
|
Size and Weight
Software filter
|
Digital FIR Butterworth 8th order, bypass possible, 5 kHz max. corner frequency
|
Size and Weight
Electrical isolation of inputs
|
Channel to channel and channel to supply
|
Size and Weight
Max. common mode voltage
|
±(100 V - [Vin]) channel to supply ground, [1]
|
Size and Weight
|
Vin ≤± 60 V
|
Size and Weight
Input impedance
|
> 2 MΩ II < 2 nF (±10 V, ±60 V)
|
Size and Weight
|
> 10 MΩ II < 2 nF (±1 V, ±100 mV)
|
Size and Weight
Accuracy (up to +85 °C / +185 °F)
|
|
Size and Weight
Measurement error (MR: 100 mV)
|
±[0.15 % + 100 ppm/K x |T -25 °C|] x MR ±0.12 % x Vin
|
Size and Weight
Measurement error (MR: 1 V)
|
±[0.05 % + 10 ppm/K x |T - 25 °C|] x MR ±0.1 % x Vin
|
Size and Weight
Measurement error (MR: 10 V)
|
±[0.03 % + 5 ppm/K x |T - 25 °C|] x MR ±0.1 % x Vin
|
Size and Weight
Measurement error (MR: 60 V)
|
±[0.027 % + 60 ppm/K x |T -25 °C|] x MR ±0.22 % x Vin
|
Size and Weight
Support by ETAS Software
|
|
Size and Weight
|
Supported by INCA V5.4.1 and up via add-on (part of ES410 delivery), INTECRIO V3.x, ES400 configuration and integration tool for XCP applications
|
Contact us
Do you have any questions? Feel free to send us a message. We will be more than happy to help.