Skip to main content
ES132.1 interface extension module

State-of-the-art CAN FD extension

A visual of the ES132.1 interface extension module

The ES132.1 interface extension module detects signals from ECU interfaces and vehicle buses. It is designed for vehicle ECU calibration, diagnostics, and flash programming. It enables the easy extension of a set-up with additional CAN FD channels and supports multi-client host connections. The module can be integrated with third-party tools and infrastructures.

Your benefits

High performance

Improves baud rate up to 8 MBit with signal improvement capability (SIC) ransceiver.

Full reliability

Facilitates high level of stability with robust LEMO connectors/ splash water protection.

Scalable and integrable

Makes the set-up scalable and allows easy integration into other applications.

Advanced connectivity functions: full flexibility

Image shows diagram with example set-up of the ES132.1 interface extension module

The ES132.1 interface extension module comes with a wide range of state-of-the-art connectivity options specifically for the automotive industry:

  • Connection to two independent CAN FD channels
  • Connection to FE ports of other ETAS hardware devices using ETAS time synchronization hardware
  • Support of CAN bus interface and SAE J2534-2 pass through
  • Rendering of third-party software compatibility with ETAS BOA
  • Equipped with the latest technology using SIC transceivers

ETAS Downloads

Icon document download

ETAS Download Center provides abundant information on ETAS Products and Solutions, in the form of flyers, brochures, technical articles, or manuals. You will also find hotfixes and software updates.

Technical data

Size and Weight
Size and Weight
Dimensions (HxWxD)
92 mm x 48 mm x 24 mm / 3.62 in x 1.89 in x 0.92 in (housing)
Size and Weight
Dimension with the Integrated Cable
24 mm x 48 mm x 1592 mm / 0.95 in x 1.89 in x 62.68 in
Size and Weight
Weight
0.18 kg / 0.4 lb (with cable)
Size and Weight
Environment
Size and Weight
Temperature range
-40 °C to +60 °C / -40 °F to +140 °F (operation)
Size and Weight
-40 °C to +85 °C / -40 °F to +185 °F (transport and storage)
Size and Weight
Relative humidity range
15 % to 95 %, non-condensing
Size and Weight
Ingress Protection
IP42
Size and Weight
Power supply
Size and Weight
Power consumption
<500 mA Input current at 12V
Size and Weight
Operating Voltage
6 V- 32 V
Size and Weight
CAN FD / CAN interfaces
Size and Weight
Number of channels
2 CAN-FD SIC channels, with DSUB9 male connector
Size and Weight
SAE J2534 Pass Thru Interface
For use of the ES132.1 with 3rd party software applications. The J2534 interface is included in the ETAS ECU and Bus Interfaces Package (EBI-IP). This package can be downloaded from ETAS homepage.
Size and Weight
CAN FD Variant support
In CAN FD mode the protocol variants ISO / Non-ISO is software-configurable for each channel individually.
Size and Weight
Protocols
CAN 2.0B ISO 11898-1 and ISO ISO15765-4, ISO11898-2:2016
Size and Weight
CAN-Transceiver (Physical Layer)
High-speed SIC transceiver (TJA1462 ), Standard (V2.0a) or Extended Format (V2.0b), ISO High-speed mode, CAN-FD (non ISO CAN FD V1 and ISO 11898-2:2015 )
Size and Weight
Maximum baud rate for CAN
1 Mbit/s
Size and Weight
Maximum baud rate for CANFD
8 Mbit/s
Size and Weight
Electrical isolation
The CAN Interfaces are electrically isolated from the Host (Ethernet) interface
Size and Weight
Acquisition of synchronous data
Size and Weight
ES132.1 supports the ETAS Hardware Time Synchronization, i.e., connected to an FE connection on an ETAS device it is synchronized with 1µs to the other signals in that system.
Size and Weight
Size and Weight
Host requirements
Size and Weight
Ethernet
100BASE-T
Size and Weight
Connection
Lemo Connector, coded for ETAS FE sockets
Size and Weight
Status display
Size and Weight
LEDs
Operating state, interfaces
Size and Weight
Software support
Size and Weight
Firmware Update
Supported as of HSP V13.5.0
Size and Weight
INCA
Supported as of INCA V7.4.5
ES132.1 is integrated native into INCA like any other ETAS HW device.
Size and Weight
Supported use cases
INCA supports all available CAN protocols on the ES132.1.
ES132.1 supports CAN based measurement modules
Size and Weight
3rd Party SW support
Easy integration in any application by using the ETAS Bus Interfaces Integration Package (EBI-IP)
Size and Weight
Diagnostics
ODX-LINK V1.3 or higher, ODX-Flash
Size and Weight
Delivery content
Size and Weight
Accessories
CAN 120 ohm Termination Resistor 2xDSUB, CAN Interface Cable, OBDII J1962 - DSUB (16mc-9fc), 2m, CAN and FlexRay Interface Y-Cable, DSUB – 2 x DSUB (9fc-9mc+9mc), 0m3, CAN, LIN and FlexRay interface cable, DSUB-DSUB (9fc - 9mc + 9fc), 2 m
Size and Weight
ECU and BUS Interface module
ES132.1 CAN FD (2 x CAN FD) interface extension module with Lemo 1B FGC (8mc) Ethernet connection.
Including Y-Cable CBCF100.1-0m3

Contact us

Do you have any questions? Feel free to send us a message. We will be more than happy to help.

Contact us today!